[. . . ] Refer to the most recent product announcement or contact your local Hitachi Data Systems sales office for information on feature and product availability. This document contains the most current information available at the time of publication. When new and/or revised information becomes available, this entire document will be updated and distributed to all registered users. Trademarks Hitachi Data Systems is a registered trademark and service mark of Hitachi, Ltd. , and the Hitachi Data Systems design mark is a trademark and service mark of Hitachi, Ltd. HP-UX, MC/ServiceGuard, and Tru64 are trademarks or registered trademarks of the Hewlett-Packard Development Company, L. P. [. . . ] The host as iSCSI initiator discovers the iSCSI target with iSCSI disk array subsystem information registered on the iSNS Server. On the Tools menu, click Configuration Settings or click the Configuration Settings button on the toolbar. Click the iSNS tab. ­ iSNS Server: Specify whether to use iSNS Server or not. When using the iSNS server, specify the IP Address and Port Number of the iSNS Server. 3. Click the Apply button. 130 Chapter 7 Configuring Storage on the Thunder 9530TM V Series Subsystem 4. Click the OK button. 7. 3. 3 Sending a Ping To send the ping to the initiator (host) and display the result of the sending, follow these steps: 1. On the Tools menu, click the Configuration Settings or click the Configuration Settings button on the toolbar. Click the Ping tab. ­ ­ Port: Select the port to send ping. Destination IP Address: Specifiy the IP Address of the initiator. 3. Click the Start button. Acer | ASPIRE V5-531P User and Reference Guide 131 4. As necessary, select the Refresh button to display the latest information. 132 Chapter 7 Configuring Storage on the Thunder 9530TM V Series Subsystem 7. 4 Determining Space and RAID Level Requirements This process will depend on the customer requirements, however Acer | HDS recommends certain configuration guidelines that will provide good performance and adequate protection of data integrity in most circumstances. Depending on whether there are formatted logical units in the RAID group or not, the message description is different. ­ When no logical unit exists in the RAID Group: Acer | ASPIRE V5-531P User and Reference Guide 141 When a logical unit exists in the RAID Group: 142 Chapter 7 Configuring Storage on the Thunder 9530TM V Series Subsystem 7. 4. 5 Setting a Logical Unit Note: You can create settings for the only system LU when the AMS200 is connected to the NAS in accordance with the following restrictions: No. Internal LU Number (Note1) 0 1 2 3 4 5 6 7 8 System LU Capacity Restriction Bytes Designation Block Designation Control unit in charge (Note2) 0 1 0 1 0 0 0 0 0 1 2 3 4 5 6 7 8 9 For system disk (CTL 0) For system disk (CTL 1) For volume for storing dump (CTL 0) For volume for storing dump (CTL 1) For command device For the work for storing the dump edit result. For the system sharing volume For the volume for back-upping a shared volume For the volume 2 for back-upping a shared volume 14, 013 M bytes (or more) 14, 013 M bytes (or more) 4, 925 M bytes (or more) 4, 925 M bytes (or more) 35 M bytes (or more) 4, 195 M bytes (or more) 2, 537 M bytes (or more) 2, 537 M bytes (or more) 2, 537 M bytes (or more) 27, 369, 141 blocks (or more) 27, 369, 141 blocks (or more) 9, 619, 141 blocks (or more) 9, 619, 141 blocks (or more) 68, 360 blocks (or more) 8, 193, 360 blocks (or more) 4, 955, 079 blocks (or more) 4, 955, 079 blocks (or more) 4, 955, 079 blocks (or more) Note1: Internal LU Number is recommended value. If value other than the values described above is set, there is no problem in system operation. If value other than the values described above is set, there is no problem in system operation. Note: It is recommended that system LU and user LU when the AMS200 is connected to the NAS are created in different RAID groups respectively. Note: If the power supply has already been turned on, proceed to the next step. Start the Storage Navigator-Modular program, and set the operation mode to Management Mode. Click the icon of an array unit on the Main window, select the Settings menu, and then click Display Details. Click the icon of a RAID group from which you would like to create the Logical Unit. This operation can also be completed from the context menu of the Logical Unit dialog box. [. . . ] RKAJ 1 30 2 45 3 60 4 75 5 90 6 105 15 (Max) 28D+2P 0 0. 00 0 0. 00 0 0. 00 0 0. 00 29 3869. 27 30 4012. 58 29 3869. 27 30 4012. 58 58 7738. 55 60 8025. 17 58 7738. 55 60 8025. 17 87 11607. 83 90 12037. 75 87 11607. 83 90 12037. 75 Table F. 10 Disk capacity Componen t unit Range Total range of Disk drives 2D+2D List of Capacities Corresponding to RAID1+0 (146 Gbytes) 143. 3 G bytes RKS 1 Min. RKAJ 1 30 2 45 3 60 4 75 5 90 6 105 15 (Max) 3D+3D 4D+4D 5D+5D 6D+6D 7D+7D 8D+8D 4 286. 61 6 429. 91 8 573. 22 10 716. 53 12 859. 83 14 1003. 14 0 0. 00 12 859. 83 12 859. 83 8 573. 22 10 716. 53 12 859. 83 14 1003. 14 0 0. 00 28 2006. 29 30 2149. 59 24 1719. 67 30 2149. 59 24 1719. 67 28 2006. 29 16 1146. 45 44 3152. 74 42 3009. 43 40 2866. 13 40 2866. 13 36 2579. 51 42 3009. 43 32 2292. 90 60 4299. 19 60 4299. 19 56 4012. 58 60 4299. 19 60 4299. 19 56 4012. 58 48 3439. 35 72 5159. 03 72 5159. 03 72 5159. 03 70 5015. 73 72 5159. 03 70 5015. 73 64 4585. 81 88 6305. 49 90 6448. 79 88 6305. 49 90 6448. 79 84 6018. 87 84 6018. 87 80 5732. 26 104 7451. 94 102 7308. 63 104 7451. 94 100 7165. 33 96 6878. 71 98 7022. 02 96 6878. 71 336 Appendix F List of Storage Capacities Corresponding to RAID Levels and Configurations Table F. 11 Disk capacity Componen t unit Range Total range of Disk drives 2D List of Capacities Corresponding to RAID0 (300 Gbytes) 287. 6 G bytes RKS 1 Min. RKAJ 1 30 2 45 3 60 4 75 5 90 6 105 15 (Max) 3D 4D 5D 6D 7D 8D 9D 10D 11D 12D 13D 14D 15D 16D 2 575. 25 3 862. 88 4 1150. 51 5 1438. 14 6 1725. 77 7 2013. 40 8 2301. 02 9 2588. 65 10 2876. 28 11 3163. 91 12 3451. 54 13 3739. 17 14 4026. 80 15 4314. 42 0 0. 00 14 4026. 80 15 4314. 42 12 3451. 54 15 4314. 42 12 3451. 54 14 4026. 80 8 2301. 02 9 2588. 65 10 2876. 28 11 3163. 91 12 3451. 54 13 3739. 17 14 4026. 80 15 4314. 42 0 0. 00 30 8628. 85 30 8628. 85 28 8053. 60 30 8628. 85 30 8628. 85 28 8053. 60 24 6903. 08 27 7765. 97 30 8628. 85 22 6327. 82 24 6903. 08 26 7478. 34 28 8053. 60 30 8628. 85 16 4602. 05 44 12655. 65 45 12943. 28 44 12655. 65 45 12943. 28 42 12080. 40 42 12080. 40 40 11505. 14 45 12943. 28 40 11505. 14 44 12655. 65 36 10354. 62 39 11217. 51 42 12080. 40 45 12943. 28 32 9204. 11 60 17257. 71 60 17257. 71 60 17257. 71 60 17257. 71 60 17257. 71 56 16107. 20 56 16107. 20 54 15531. 94 60 17257. 71 55 15819. 57 60 17257. 71 52 14956. 68 56 16107. 20 60 17257. 71 48 13806. 17 74 21284. 51 75 21572. 14 72 20709. 25 75 21572. 14 72 20709. 25 70 20134. 00 72 20709. 25 72 20709. 25 70 20134. 00 66 18983. 48 72 20709. 25 65 18695. 85 70 20134. 00 75 21572. 14 64 18408. 22 90 25886. 57 90 25886. 57 88 25311. 31 90 25886. 57 90 25886. 57 84 24160. 80 88 25311. 31 90 25886. 57 90 25886. 57 88 25311. 31 84 24160. 80 78 22435. 03 84 24160. 80 90 25886. 57 80 23010. 28 104 29913. 37 105 30201. 00 104 29913. 37 105 30201. 00 102 29338. 11 105 30201. 00 104 29913. 37 99 28475. 23 100 28762. 85 99 28475. 23 96 27612. 34 104 29913. 37 98 28187. 60 105 30201. 00 96 27612. 34 Table F. 12 Disk Capacity Component Unit Range Total Range of Disk Drives 1D+1D List of Capacities Corresponding to RAID1 (300 Gbytes) 287. 6 G bytes RKS 1 Min. 15 (Max) 1 30 2 45 3 60 RKAJ 4 75 5 90 6 105 2 287. 62 14 2013. 40 30 4314. 42 44 6327. 82 60 8628. 85 74 10642. 25 90 12943. 28 104 14956. 68 Acer | ASPIRE V5-531P User and Reference Guide 337 Table F. 13 Disk capacity Componen t unit Range Total range of Disk drives 2D+1P List of Capacities Corresponding to RAID5 (300 Gbytes) 287. 6 G bytes RKS 1 Min. [. . . ]